Hàng Châu Liên minh Công nghiệp khí Thiết bị Công ty TNHH

Chất lượng cao

Trang Chủ
Các sản phẩm
Về chúng tôi
Tham quan nhà máy
Kiểm soát chất lượng
Liên hệ chúng tôi
Yêu cầu báo giá
Tin tức
Nhà Sản phẩmNhà máy khí Oxygen

Medical Oxygen Gas Plant / Liquid Nitrogen Generation Plant Of High Purity

Tôi trò chuyện trực tuyến bây giờ
Trung Quốc Hangzhou Union Industrial Gas-Equipment Co., Ltd. Chứng chỉ
Trung Quốc Hangzhou Union Industrial Gas-Equipment Co., Ltd. Chứng chỉ
The quality and service are good, delivery time is punctual every time.

—— Russian Seles

My customer is very satisfied with your sample, now we place an order with you.

—— Russian Porova

Medical Oxygen Gas Plant / Liquid Nitrogen Generation Plant Of High Purity

Medical Oxygen Gas Plant / Liquid Nitrogen Generation Plant Of High Purity
Medical Oxygen Gas Plant / Liquid Nitrogen Generation Plant Of High Purity Medical Oxygen Gas Plant / Liquid Nitrogen Generation Plant Of High Purity

Hình ảnh lớn :  Medical Oxygen Gas Plant / Liquid Nitrogen Generation Plant Of High Purity Giá tốt nhất

Thông tin chi tiết sản phẩm:
Place of Origin: Zhejiang ,China ( mainland)
Hàng hiệu: UIG
Chứng nhận: ISO 9001:2000
Model Number: KDO,KDN,KDON,KLN,KZO
Thanh toán:
Minimum Order Quantity: 1 SET
Giá bán: Negotiation
Packaging Details: Sea Worthy Packing
Delivery Time: 120 Days
Payment Terms: T/T ,L/C
Supply Ability: 2-3 Sets Per Month
Chi tiết sản phẩm
O2 purity: ≥99.6 Gox purity: 99.6|≥99.6
Product name: Air Separation Plant Production capacity: 600 M3/hour
Compressor Capacity: 3600 Nm3/h Working Pressure: 0.95MPa
Điểm nổi bật:

oxygen nitrogen gas plant

,

industrial oxygen gas plant

Medical Oxygen Gas Plant / Liquid Nitrogen Generation Plant Of High Purity

 

 

Quick Details:

 

Condition: new

Place of origin: China(mainland)

Brand name: UIG

Model number: KDON-600/120 Oxygen Plant,

Production capacity:600 M3/hour

Certification: ISO 9001:2000

Warranty:1 year

Life:20 years with proper maintenance

After-sales service provided: Engineers available to service plants overseas

Usage: Industrial and medical (oxygen)

UIG Air separation plants are designed for a vast range of capacities and products summarized below: FOR OXYGEN 99.7 % 

 

 

Specifications:

 

1.1 

Products

 

Capacity

 

(m3/h)

Purity

 

(%)

MAX.Pressure 

 

(bar)

Dewpoint

 

(℃)

O2

 

600±5%

≥99.6

160

-70

N2

 

120±5%

≥99.99

8(booster 147)

-70

1.2

Ntinuous operation period

 

≥24 months

Defrost Period

 

12 Hours

Starting time 

                      

8-12 Hours

Process  air

 

 

Compressor  Capacity

 

3600 Nm3/h

Working  Pressure

 

0.95MPa

Power

 

 

Air compressor

 

500(Shaft power 461)KW

Air pre-cooler

 

22 KW

Power of heater

 

72 KW(18KW)

Booster

 

90 KW

Liquid Oxygen Pump 

(16.5 MPa)

11 KW

Nitrogen compressor

 

30KW

Cooling Water

 

80t/hr

 

 

 

 2. Public Works Conditions

 

Raw Air Composition

 

N2+Ar

O2

H2O

Σ

V%

≥79.0

≤21.0

Saturated

100.0

Atmosphere Condition

 

Atmosphere Temperature

 

20℃

Atmospheric Pressure

 

968mba(<500M)

Cooling Water Conditions

 

Used circulating cooling water

 

Inlet Temperature

 

≤30   ℃

Max Pressure Drop

 

0.2   MPa

Max Temperature Increase

 

10      ℃

Hardness

             

15    Germany Degree

Turbidity Co-efficiency

 

0.0004   m2K/W

PH 

 

7-8

Sediments

 

0.5      mg

Power Condition

 

Voltage

 

380±5%V

Frequency

 

50     HZ

AC Three phase four wire system, neutral point directly earthed

 

 

 

Description:

 

The Plant uses normal temperature molecular sieve adsorption, medium pressure booster expansion  reflux flow.

Raw air is sucked from the atmosphere,It is going through filter for removal of dust and mechanical  impurities.,then it is compressed to a certain degree by single stage screw compressor,via end stage  cooler, air pre-cooling system, the air is cooled to approx. 8℃. After water separation moisture is  separated in water separator and then it goes to purifier for removal of moisture, CO2, C2H2 and  hydrogen dioxide. 

Then most part of air enters main heat exchanger to be cooled to saturated tempt. and partly is liquefied  to the lower part of lower column; another part of air is compressed to a certain degree through two  stage compression booster, via end stage cooler enters into oxygen heat exchanger to be cooled to be  near saturated temperature, then after throttle goes to lower column. Through lower column pre-distillation  we can get enriched oxygen liquid air from the bottom of the column. After cooling through sub-cooler, after throttled it goes to the middle part of upper column as reflux liquid for rectification. WN is obtained  from the top of lower column, after condensed through condenser-evaporator, a part of WN is used as rectification reflux liquid for lower column; another part after cooling  through sub-cooler and after throttling goes to the top of upper column as rectification reflux liquid. Pure  liquid oxygen is obtained from the bottom of upper column, and it is condensed by condenser-evaporator. Liquid oxygen is abstracted from the bottom after cooling through sub-cooler, then it goes to  LOX pump to be pressurized. It is evaporated in O2 heat exchanger and is reheated to normal tempt.

WN from the top of upper column goes through sub-cooler, the ower part of main heat exchanger to be  reheated to a certain tempt. Then it goes to expansion turbine to create cold and returns to sub-cooler  and main heat exchanger again to be reheated to normal tempt. A part of it passes to purifier as  regenerating gas resource and another part goes to be vented partly. 

 

Competitive Advantage:

 

* This oxygen plant adopts cryogenic separation process. Oxygen is obtained by inner compression, so it 

can be both for medical & industrial usage and to be filled into cylinder.

* This development and design of flow is new, my company use the technology to mature.

* Simple operation, convenient maintenance, starting time is short, unit power consumption is low.

* Oxygen of high purity and very stable, meet and exceed technical indicators of 2010in china.

* Whole set of plant adopts skid mount type and connected with high-pressure hose between individual 

machines/equipments. So, it shorten installation period accordingly.

* Complete equipment, installation and removal is very simple, easy to move to another area operations.

* Cooling mode of plant adopts air cooling for whole set of plant, no cooling water system required so it also 

save investment cost for the owner.

* Security -- The outside compression process is oxygen be compressed at room temperature, The inside 

compression process is liquid oxygen be compressed at low temperature, Security than more with the  inside 

compression process; Extraction a lot of liquid oxygen from evaporation-condenser, To ensure that no 

accumulation of hydrocarbons; Evaporation of high pressure with liquid oxygen, reducing the possibility of

 hydrocarbon accumulation; Reducing fire hazards.

*  Reliability - liquid oxygen pump excellent performance, easy to maintain; Booster compressor is one or two 

compression, oxygen compressor Booster compressor is three or five compression, High reliability with 

booster compressor.

Medical Oxygen Gas Plant / Liquid Nitrogen Generation Plant Of High Purity 0

 

Chi tiết liên lạc
Hangzhou Union Industrial Gas-Equipment Co., Ltd.

Người liên hệ: Alice

Tel: +8613735413366

Gửi yêu cầu thông tin của bạn trực tiếp cho chúng tôi